Table2.Power-supplyLEDsstatusandrequiredaction(continued)
Power-supplyLEDs
AC
(green)
DC
(green)
Error
(yellow)DescriptionActionNotes
OnOffor
Flashing
On
Faultypower
supply
Replacethepowersupply.
OnOnOn
Powersupplyis
faultybutstill
operational
Replacethepowersupply.
Serverpowerfeatures
Whentheserverisconnectedtoapowersourcebutisnotturnedon,theoperatingsystemdoesnotrun,
andallcorelogicexceptfortheintegratedmanagementmoduleII(IMM2)isshutdown.
However,theservercanrespondtorequestsfromtheIMM2,suchasaremoterequesttoturnontheserver.
Thepower-onLEDflashestoindicatethattheserverisconnectedtopowerbutisnotturnedon.
Turningontheserver
Usethisinformationtoturnontheserver.
Approximately40secondsaftertheserverisconnectedtopower,thepower-controlbuttonbecomesactive,
andoneormorefansmightstartrunningtoprovidecoolingwhiletheserverisconnectedtopower.Youcan
turnontheserverandstarttheoperatingsystembypressingthepower-controlbutton.
Theservercanalsobeturnedoninanyofthefollowingways:
•Ifapowerfailureoccurswhiletheserveristurnedon,theserverwillrestartautomaticallywhenpower
isrestored.
•IfyouroperatingsystemsupportstheWakeonLANfeature,theWakeonLANfeaturecanturnonthe
server.
For32-bitoperatingsystemsonly:Somememoryisreservedforvarioussystemresourcesandis
unavailabletotheoperatingsystem.Theamountofmemorythatisreservedforsystemresourcesdepends
ontheoperatingsystem,theconfigurationoftheserver,andtheconfiguredPCIoptions.
Turningofftheserver
Usethisinformationtoturnofftheserver.
Whenyouturnofftheserverandleaveitconnectedtopower,theservercanrespondtorequestsfromthe
IMM2,suchasaremoterequesttoturnontheserver.Whiletheserverremainsconnectedtopower,
oneormorefansmightcontinuetorun.Toremoveallpowerfromtheserver,youmustdisconnectit
fromthepowersource.
Someoperatingsystemsrequireanorderlyshutdownbeforeyouturnofftheserver.Seeyour
operating-systemdocumentationforinformationaboutshuttingdowntheoperatingsystem.
Statement5
Chapter1.TheLenovoSystemx3650M4BDType5466server19