Lenze · i700 servo inverter · reference manual · DMS 3.0 EN · 06/2016 · TD06 162
5 Motor control & motor settings
5.14 Parameterising the V/f characteristic control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2BA6 | 0x33A6 - Flying restart: Result
Setting range (min. value | unit | max. value) Lenze setting
0 ms 10000 0 ms
Write access CINH OSC P RX TX UNSIGNED_16
Output of the speed found for acceptance in the control.
This information is pending until the control reports acceptance of the found speed to the i700 servo inverter via
bit 0 in the Lenze control word (0x2830
or 0x3030 for axis B).
Sub. Name Lenze setting Data type
1 Flying restart: Determined speed [rpm] INTEGER_16
2 Flying restart: Determined speed [n unit] INTEGER_32
Subindex 1: Flying restart: Determined speed [rpm]
Display area (min. value | unit | max. value) Initialisation
-32768 r/min 32767
Write access CINH OSC P RX TX INTEGER_16
Subindex 2: Flying restart: Determined speed [n unit]
Display area (min. value | unit | max. value) Initialisation
-480000 [n unit] 480000
Write access CINH OSC P RX TX
Scaling: 480000/2
31
INTEGER_32