Lenze · i700 servo inverter · reference manual · DMS 3.0 EN · 06/2016 · TD06 294
9 Diagnostics & error management
9.4 CiA402 error codes / error messages
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Error code 0xFF03: Fatal internal error - overflow task [value]
Text ID: 0x1D
Error code 0xFF04: PLI - motor movement too large
Text ID: 0x1E
Synchronous motor (SM): Pole position identification
Error code 0xFF05: STO inhibited
Text ID: 0x1F
Error code 0xFF06: Max. speed reached
Text ID: 0x20
Error code 0xFF07: Impermissible during identification or in the test mode
Text ID: 0x21
Error code 0xFF08: Impossible during identification
Text ID: 0x23
Cause Remedies Response
Internal error 24 V mains switching required.
If the error occurs frequently,
please contact Lenze.
Fault
Cause Remedies Response
Motor moved too much during pole
position identification.
Check settings of the pole
position identification in
0x2C62
| 0x3462.
If this error takes place in pole
position identification without
any motion, the motor has to be
stalled.
Fault
(adjustable in 0x2C60
| 0x3460)
Cause Remedies Response
The servo inverter is inhibited via STO
terminals, despite controller enable
via the control word.
Deactivate STO or inhibit the
servo inverter.
Check the cabling of the STO
terminals.
Warning with change to the "Switch
on disabled" device status.
Cause Remedies Response
Motor speed too high. Reduce motor speed.
Check resolver or cabling.
Fault
(adjustable in 0x2D44:2
| 0x3544:2)
Threshold can be adapted in
0x2D44:1
| 0x3544:1.
Cause Remedies Response
A parameter was attempted to
change which influences the
identification in progress or the
currently activated test mode.
Postpone changing the parameter
until the identification is completed
or the test mode is deactivated again.
Warning
Cause Remedies Response
A parameter was attempted to
change which influences the
identification in progress.
Postpone changing the parameter
until the identification is completed.
Warning