11 Appendix
11.1 Table of attributes
318
Lenze · i700 servo inverter · reference manual · DMS 3.0 EN · 06/2016 · TD06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2D49 Motor temperature monitoring: Parameter
1: Motor temperature monitoring: Sensor type UNSIGNED_8 - P
2: Motor temperature monitoring: Response UNSIGNED_8 - P
3: Motor temperature monitoring: Warning
threshold
INTEGER_16 1/10 P
4: Motor temperature monitoring: Error
threshold
INTEGER_16 1/10 P
5: Motor temperature monitoring: Actual motor
temperature
INTEGER_16 1/10 OSC Tx
6: Thermal sensor characteristic: Grid point 1 -
temperature
INTEGER_16 1/10 P
7: Thermal sensor characteristic: Grid point 2 -
temperature
INTEGER_16 1/10 P
8: Thermal sensor characteristic: grid point 1 -
resistance
INTEGER_16 - P
9: Thermal sensor characteristic: grid point 2 -
resistance
INTEGER_16 - P
0x2D4C
Motor utilisation (I²xt): Parameter for the thermal model
1: Motor utilisation (I²xt): Thermal time constant
- winding
UNSIGNED_16 - P
2: Motor utilisation (I²xt): Thermal time constant
- laminations
UNSIGNED_16 - P
3: Motor utilisation (I²xt): Influence of the
winding
UNSIGNED_8 - P
4: Motor utilisation (I²xt): Starting value UNSIGNED_16 - P
0x2D4D
Motor utilisation (I²xt): User-definable characteristic
1: I²xt: x1 = n01/nN (n01 ~ 0) UNSIGNED_16 - P
2: I²xt: y1 = i01/iN (x = n01 ~ 0) UNSIGNED_16 - P
3: I²xt: x2 = n02/nN (n02 = limit - reduced
cooling)
UNSIGNED_16 - P
4: I²xt: y2 = i02/iN (x = n02 = limit - reduced
cooling)
UNSIGNED_16 - P
5: I²xt: x3 = n03/nN (n03 = rated speed) UNSIGNED_16 - P
6: I²xt: y3 = i03/iN (x = n03 = rated speed) UNSIGNED_16 - P
7: I²xt: x4 = n04/nN (n04 = limit - field
weakening)
UNSIGNED_16 - P
8: I²xt: y4 = i04/iN (x = n04 = limit - field
weakening)
UNSIGNED_16 - P
0x2D4E
Motor utilisation (I²xt): Motor overload warning
threshold
UNSIGNED_16 - P
0x2D4F
Motor utilisation (I²xt): Actual utilisation UNSIGNED_16 - OSC Tx
0x2D50 Motor utilisation (I²xt): Motor overload error
1: Motor utilisation (I²xt): Response UNSIGNED_8 - P
2: Motor utilisation (I²xt): Error threshold UNSIGNED_16 - P
0x2D51
Monitoring: Position and velocity error
1: Monitoring: Velocity error - error threshold UNSIGNED_32 - P
2: Monitoring: Velocity error - minimum error
time
UNSIGNED_16 - P
3: Monitoring: Velocity error - response UNSIGNED_8 - P
4: Monitoring: Position error - error threshold UNSIGNED_32 - P
5: Monitoring: Position error - minimum error
time
UNSIGNED_16 - P
6: Monitoring: Position error - response UNSIGNED_8 - P
0x2D81
Counter: Operating time
1: Device: Operating time UNSIGNED_32 -
2: Device: Power-on time UNSIGNED_32 -
0x2D82 Motor: Actual voltage - Veff, phase-phase UNSIGNED_32 1/10 OSC Tx
Index Name Data type Factor Attributes
Greyed out = read only