Lenze · i700 servo inverter · reference manual · DMS 3.0 EN · 06/2016 · TD06 319
11 Appendix
11.1 Table of attributes
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2D83 Motor: Phase currents
1: Zero system current INTEGER_32 1/100 OSC Tx
2: Current - phase U INTEGER_32 1/100 OSC Tx
3: Current - phase V INTEGER_32 1/100 OSC Tx
4: Current - phase W INTEGER_32 1/100 OSC Tx
0x2D84 Heatsink temperature
1: Heatsink temperature: Actual temperature INTEGER_16 1/10 OSC
2: Heatsink temperature: Warning threshold INTEGER_16 1/10 P
3: Heatsink temperature: Threshold - switch-on
fan
INTEGER_16 1/10 P
4: Heatsink temperature: Threshold - switch-off
fan
INTEGER_16 1/10 P
0x2D8A
Speed monitoring: Actual speed error INTEGER_32 - OSC Tx
0x2DD0 Field: Values
1: Field: Actual field UNSIGNED_16 - OSC Tx
2: Field: Setpoint field UNSIGNED_16 - OSC Tx
0x2DD1 Motor: Currents
1: D current (id): Actual D current INTEGER_16 1/100 OSC Tx
2: Q current (iq): Actual Q current INTEGER_16 1/100 OSC Tx
3: D current (id): Setpoint D current INTEGER_16 1/100 OSC Tx
4: Q current (iq): Setpoint Q current INTEGER_16 1/100 OSC Tx
5: Motor current Ieff INTEGER_16 1/100 OSC Tx
0x2DD2 Position: Target position interpolated INTEGER_32 - OSC Tx
0x2DD3 Target speeds
1: Speed: Setpoint speed INTEGER_32 - OSC Tx
2: Speed: Setpoint speed 2 INTEGER_32 - OSC Tx
3: Speed: Limited setpoint speed INTEGER_32 - OSC Tx
0x2DD4 Speed controller: Output signal
1: Speed controller: Output signal 1 INTEGER_16 1/10 OSC Tx
2: Speed controller: Output signal 2 INTEGER_16 1/10 OSC Tx
0x2DD5 Target torque INTEGER_32 1/100 OSC Tx
0x2DD6 Torque: Filter cascade
1: Torque: Filter cascade - starting value INTEGER_16 1/10 OSC Tx
2: Torque: Notch filter 1 - input value INTEGER_16 1/10 OSC Tx
3: Torque: Notch filter 2 - input value INTEGER_16 1/10 OSC Tx
4: Torque: Filtered setpoint torque INTEGER_16 1/10 OSC Tx
0x2DD7 Voltage values
1: Actual motor voltage limit: Actual voltage INTEGER_16 1/10 OSC Tx
2: D-current controller: Output signal INTEGER_16 1/10 OSC Tx
3: Q-current controller: Output signal INTEGER_16 1/10 OSC Tx
4: D-voltage (magnetisation) INTEGER_16 1/10 OSC Tx
5: Q-voltage (torque) INTEGER_16 1/10 OSC Tx
0x2DDC Slip: Actual slip INTEGER_16 1/10 OSC Tx
0x2DDD Device: Actual output frequency INTEGER_16 1/10 OSC Tx
0x2DDE Motor: Actual position of rotor angle INTEGER_16 - OSC Tx
0x2DDF Axis: Device data
1: Axis: Rated current UNSIGNED_16 1/100 OSC Tx
2: Axis: Maximum current UNSIGNED_16 1/100 OSC Tx
UNSIGNED_16
1/10
9
Tx
UNSIGNED_16
1/10
8
Tx
5: Axis: Supported feedback type UNSIGNED_8 - Tx
Index Name Data type Factor Attributes
Greyed out = read only