11 Appendix
11.2 Structure of the parameter set file
334
Lenze · i700 servo inverter · reference manual · DMS 3.0 EN · 06/2016 · TD06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
"PAR_ParamErrorHeader" header type
If the identification "2" is given for the data area type, the error messages are successively arranged
in the following layout within the data area:
Byte offset
0 4 6
... Error code Index Subindex ...
Byte
offset
Meaning Info
0 Error code in accordance with CiA301 or
EtherCAT
SDO abort code which was generated when the object
with the following index/subindex combination was
accessed.
SDO abort codes (Abort codes)
( 16)
4 Index of the parameter object Index of the parameter in the object directory which the
error code belongs to.
6 Subindex of the parameter object Subindex of the parameter in the object directory which
the error code belongs to.