Technical data
Leuze electronic RSL 430 105
Tab.15.4: Protective field range
Device range S M L XL
Resolution [mm] Protective field range [m]
150 3.00 4.50 6.25 8.25
70 3.00 4.50 6.25 8.25
60 3.00 4.50 6.25 8.25
50 3.00 4.50 6.25 6.25
40 3.00 4.50 4.50 4.50
30 3.00 3.50 3.50 3.50
Tab.15.5: Warning field data
Safety sensor RSL410 RSL420
RSL425
RSL430 RSL440
RSL445
Number of field pairs 1 10 10 + 10 100
Warning field range 0…20m
Object size 150mmx150mm
Diffuse reflectance WF minimum Min. 10%
Tab.15.6: Measurement field data
Detection range 0…50 m
Diffuse reflection 90%
Radial resolution 1mm
Lateral resolution 0.1 °
Tab.15.7: Electrical supply
RSL430, RSL440 voltage supply 24VDC (+20% / -30%)
Power supply unit/battery Supply acc. to IEC 742 with secure mains supply
isolation and equalization for power outages of up
to 20 ms acc. to EN 61496-1.
Overcurrent protection Via 2A semi-time-lag fuse in the cabinet
Note: With high external loads at the switching out-
puts (total current > 700mA), the fuse rating must
be adjusted to 2.5A.
Current consumption Approx.700mA (use power supply unit with 3A)
Power consumption 17W with 24V plus output capability
Overvoltage protection overvoltage protection with protected limit stop
Protective conductor Connection required
Device connection Connection cable, 29-wire
Connection socket for Ethernet/communication M12-4 connector, D-coded