Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x101D).
status 32s 6
Reply status. For a list of status codes, see Commands on page
446.
Reply
Simulate Unaligned
The Simulate Unaligned command simulates data before alignment transformation.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x452A).
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x452A).
status 32s 6
Reply status. For a list of status codes, see Commands on page
446.
Reply
Acquire
The Acquire command acquires a new scan.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4528).
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4528).
status 32s 6
Reply status. For a list of status codes, see Commands on page
446.
Reply
The command returns after the scan has been captured and transmitted.
Acquire Unaligned
The Acquire Unaligned command acquires a new scan without performing alignment transformation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2380 and is the answer not in the manual?

LMI Technologies Gocator 2380 Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2380
CategoryAccessories
LanguageEnglish

Related product manuals