EasyManuals Logo

LMI Technologies Gocator 2380 User Manual

Default Icon
652 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #527 background imageLoading...
Page #527 background image
Gocator Line Profile Sensors: User Manual
Protocols • 528
Message Format
Command Result,measurement ID,measurement ID...
Reply If no arguments are specified, the custom format data string is used.
OK, <custom data string> ERROR, <Error Message>
If arguments are specified,
OK, <data string in standard format>
ERROR, <Error Message>
Formats
Examples:
Standard data string for measurements ID 0 and 1:
Result,0,1
OK,M00,00,V151290,D0,M01,01,V18520,D0
Standard formatted measurement data with a non-existent measurement of ID 2:
Result,2
ERROR,Specified measurement ID not found. Please verify your input
Custom formatted data string (%time, %value[0], %decision[0]):
Result
OK,1420266101,151290,0
Value
The Value command retrieves measurement values.
Message Format
Command Value,measurement ID,measurement ID...
Reply If no arguments are specified, the custom format data string is used.
OK, <custom data string> ERROR, <Error Message>
If arguments are specified,
OK, <data string in standard format, except that the decisions are not sent> ERROR,
<Error Message>
Formats
Examples:
Standard data string for measurements ID 0 and 1:
Value,0,1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2380 and is the answer not in the manual?

LMI Technologies Gocator 2380 Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2380
CategoryAccessories
LanguageEnglish

Related product manuals