EasyManuals Logo

LMI Technologies Gocator 2380 User Manual

Default Icon
652 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #493 background imageLoading...
Page #493 background image
Gocator Line Profile Sensors: User Manual
Protocols • 494
Field Type Offset Description
streamStepId 32s 56 Data stream step identifier within the stream step.
ranges[L][W] 16s 60 Surface ranges.
Surface Intensity
Field Type Offset Description
size 32u 0 Count of bytes in message (including this field).
control 16u 4 Bit 15: Last message flag.
Bits 0-14: Message type identifier. For this message, set to 9.
attributeSize 16u 6 Size of attributes, in bytes (min: 32, current: 32).
length (L) 32u 8 Surface length (rows).
width (W) 32u 12 Surface width (columns).
xScale 32u 16 X scale (nm).
yScale 32u 20 Y scale (nm).
xOffset 32s 24 X offset (µm).
yOffset 32s 28 Y offset (µm).
source 8u 32 Source
0 – Top
1 – Bottom
2 – Top Left
3 – Top Right
exposure 32u 33 Exposure (ns).
reserved[3] 8u 37
intensities[H][W] 8u 40 Surface intensities.
Surface Section
Field Type Offset Description
size 32u 0 Count of bytes in message (including this field).
control 16u 4 Bit 15: Last message flag.
Bits 0-14: Message type identifier. For this message, set to 20.
attributeSize 16u 6 Size of attributes, in bytes (min: 45, current: 45).
count (C) 32u 8 Number of profile arrays.
width (W) 32u 12 Number of points per profile array.
xScale 32u 16 X scale (nm).
zScale 32u 20 Z scale (nm).
xOffset 32s 24 X offset (µm).

Table of Contents