Gocator Line Profile Sensors: User Manual
Protocols • 513
Basic Object
Identity Object (Class 0x01)
Attribute Name Type Value Description Access
1 Vendor ID UINT 1256 ODVA-provided vendor ID Get
2 Device Type UINT 43 Device type Get
3 Product Code UINT 2000 Product code Get
4 Revision USINT
USINT
x.x Byte 0 - Major revision
Byte 1 - Minor revision
Get
6 Serial number UDINT 32-bit value Sensor serial number Get
7 Product
Name
SHORT
STRING
32
"Gocator" Gocator product name Get
TCP/IP Object (Class 0xF5)
The TCP/IP Object contains read-only network configuration attributes such as IP Address.TCP/IP
configuration via Ethernet/IP is not supported. See Volume 2, Chapter 5-3 of the CIP Specification for a
complete listing of TCP/IP object attributes.
Attribute Name Type Value Description Access
1 Status UDINT 0 TCP interface status Get
2 Configuration
Capability
UINT 0 Get
3 Configuration
Control
UINT 0 Product code Get
4 Physical Link
Object
Structure (See
description)
See 5.3.3.2.4 of CIP Specification Volume 2:
Path size (UINT)
Path (Padded EPATH)
Get
5 Interface
Configuration
Structure (See
description)
See 5.3.3.2.5 of CIP Specification Volume 2:
IP address (UDINT)
Network mask (UDINT)
Gateway address (UDINT)
Name server (UDINT)
Secondary name (UDINT)
Domain name (UDINT)
Get
Ethernet Link Object (Class 0xF6)
The Ethernet Link Object contains read-only attributes such as MAC Address (Attribute 3). See Volume 2,
Chapter 5-4 of the CIP Specification for a complete listing of Ethernet Link object attributes.