Gocator Line Profile Sensors: User Manual
Specifications • 607
All specification measurements are performed on LMI’s standard calibration target (a diffuse, painted
white surface).
Linearity Z is the worst case difference in average height measured, compared to the actual position over
the measurement range.
Resolution Z is the maximum variability of height measurements across multiple frames, with 95%
confidence.
Resolution X is the distance between data points along the laser line.
Repeatability Z is measured with a flat target at the middle of the measurement range. It is the 95%
confidence variation of the average height over 4096 frames. Height values are averaged over the full
FOV.
See Resolution and Accuracy on page 51 for more information.
ALL 2400 SERIES MODELS
Scan Rate
200 Hz (expanded full window), 400 Hz (G23xx equivalent full window), up to 5
kHz
Interface Gigabit Ethernet
Inputs Differential Encoder, Laser Safety Enable, Trigger
Outputs 2x Digital output, RS-485 Serial (115 kBaud), 1x Analog Output (4 - 20 mA)
Housing Gasketed aluminum enclosure, IP67
Input Voltage (Power) +24 to +48 VDC (9 W); Ripple +/- 10%
Operating Temp. 0 to 50° C
Storage Temp. -30 to 70° C
Mechanical dimensions, CD/FOV/MR, and the envelope for each sensor model are illustrated on the
following pages.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2380 and is the answer not in the manual?

LMI Technologies Gocator 2380 Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2380
CategoryAccessories
LanguageEnglish

Related product manuals