58
58
The GS550 System
The GS550 System
7.8
7.8
EMI / EMC
EMI / EMC
EMI/EMC (Electro-Magnetic Immunity & Electro-
Magnetic Compatibility):
EN 301 489-3 V1.4.1 (2002-08)
Clause 8.2: Limits for radiated emissions from
ancillary equipment, measured on a standalone
basis (measuring distance of 10m): Pass
Clause 8.3: Limits for conducted emissions DC
power input/ouput ports: Pass
Test metho d us e d: C ISPR 22, EN 6100 0 - 3 - 2: 2000
and EN 61000-3-3:1995+ A1:2001
All tests were performed using measurement
apparatus defined in CISPR 16-1. Radiated
emissions measurements conformed to
requirements of CISPR 16-1.
Clause 8: immunity tests
Enclosure-radio frequency electromagnetic field, EN
61000-4-3: Pass
Signal – RF common mode, EN 61000-4-6: Pass
DC Power input ports, RF common mode, EN
61000-4-6: Pass
Clause 9.2, radio frequency electromagnetic field:
Pass
Clause 9.5, radio frequency common mode: Pass
ESD (Electro-Static Discharges)
LSI products are tested against norm EN 61000-4.
Other Compliances
• SAE J159 and SAE J987
• ASME B30.5-2000
•Franklin laboratory: LSI products are safe to
use in proximity to blasting caps
•New-York City: MEA 110-05-E, in compliance
with 19.1.1(a).1 requirements of Reference
Standard RS 19-2 of the Building Code
• ABS (American Bureau of Shipping)
API Spec 2C compliant
7.9
7.9
Environmental conditions
Environmental conditions
Ambient
temperature
84º C maximum for the
sensors, and 59º C maximum
for the display
Operating
temperature
-35º C to 85º C
(-31º F to 185º F)
Humidity
range
0% to 100%