4.9 Remove Power to Administrative Workstation Units (
Netra
1
240)
OVERVIEW
This procedure will remove power from the Netra 240 AW and the external DAT tape
drive.
PROCEDURE
1. Be sure the AW has been halted. If this has not already been done, see “Halt the
Administrative Workstation,” Procedure 4.2.
2. Remove power to the DAT tape drive unit. See "Remove Power to DAT Tape
Drive Unit (Netra 240)", Procedure 4.15.
3. Remove power to the AW by pressing the ON/STBY switch “
” on the front of
the AW and holding it until the system powers down. The green system power
LED, located on the upper left corner of the front cover, will no longer be lit.
4. Open the circuit breaker for the DC power cables A and B connected to the rear
of the AW. See Figure 2-7. To open the circuit breaker, push the fuse in while
turning it counter clockwise, and pull the fuse out. The fuse-alarm LED above
the fuse will be lit once the fuse is no longer seated.
5. Detach the DC power cables A and B from the rear of the AW. See Figure 2-7.
6. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
1. Registered trademark of Sun Microsystems, Inc.
235-200-150
March 2006
ADMINISTRATIVE WORKSTATION MAINTENANCE
Procedure 4.9
Issue 3.00M Page 4.9-1