8.12.2 Connect Hardware for RMAS Data Link
PROCEDURE
1. Verify that the internal jumpers of the RS422 to RS232 converter (ED5D764-30
G17A, Black Box # IC456A-R4) are set as illustrated in Figure 8.11.3-1.
2. Connect the RS422 cable (ED5D764-30 G106, Black Box # EDN37J-00XX-MM;
where XX is the cable length in feet) between port 3 on the High Speed Interface
(HSI) and the RS422 port on the converter.
3. Connect the RS232 male to male cable (Black Box # ECM25C-0010-MM) from the
RS232 port on the converter to the Data Communication Equipment (DCE),
which may be a modem, DSU2, or router.
4. Plug the converter’s AC power adapter into a UPS 120VAC outlet. Refer to
Figures 8.11.3-2 , 8.11.3-3 and 8.11.3-4 for an illustration of the wiring
configuration for the TDMS/EADAS or RMAS data link.
5. THIS IS A SAFE STOPPING POINT.
235-200-150
January 2006
GROWTH AND DEGROWTH
Procedure 8.12.2
Issue 3.02 Page 8.12.2-1