8.7 Perform SCANS Data Link Growth
PROCEDURE
1. Enter UNIX
1
RTR Recent Change and Verify.
(a) Is MCC or STLWS terminal to be used?
For MCC, proceed to Step b.
For STLWS proceed to Step i.
(b) At MCC, ensure terminal is in command mode.
(c) At MCC, do Steps d through h.
(d) Type and enter: 199
Response: RCV PARAMETER INFO page displayed with cursor at 1.
database_name
(e) Type and enter: incore
Response: 2. review only
(f) Type and enter: n
Response: 3. journaling
(g) Type and enter: *
Response: RCV INITIALIZATION IN PROGRESS message displayed.
UNIX RTR RCV (ODIN) - Data Entry page displayed.
(h) You have completed Enter UNIX RTR Recent Change and Verify, proceed to
Step 2.
(i) At STLWS terminal, type and enter: RCV:MENU:DATA,RCVECD
Response: RCV ECD PARAMETER INFO page displayed with cursor at 1.
database_name
(j) Type and enter: incore
Response: 2. review only
(k) Type and enter: n
Response: 3. journaling
(l) Type and enter: *
Response: RCV INITIALIZATION IN PROGRESS message displayed.
UNIX RTR RCV (ODIN) - Data Entry page displayed.
2. Enter high-level forms.
(a) Type and enter: toggle
Response: Will take you to the high-level forms.
3. Insert SDL data.
1. Registered trademark in the United States and other countries, licensed exclusively through X/Open
Company, Limited.
235-200-150
October 2005
GROWTH AND DEGROWTH
Procedure 8.7
Issue 3.00B Page 8.7-1