5.10.3 Backup Incore ECD to Disk
PROCEDURE
1. At the MCC terminal, type and enter: 199 to access the ECD.
Response: 1. database_name:
2. Type and enter: incore
Response: 2. review only
3. Type and enter: n
Response: 3. journaling
4. Type and enter: *
Response: Enter Form Name:
5. Type and enter: activate
Response: 1.copy_inc_to_disk:
6. Enter CARRIAGE RETURN
Response: ODIN requests action desired.
7. Type and enter: e
Response: ODIN returns to the DATA ENTRY page.
8. Type and enter: <
Response: Transaction ended successfully
9. Continue with “Activate Balance Feature,” Subprocedure 5.10.4.
235-200-150
January 2003
ROUTINE MAINTENANCE
Procedure 5.10.3
Issue 3.00 Page 5.10.3-1