5.10.1 Populate Low Level ECD Forms for Log File Retrieval
PROCEDURE
Note: The following low level ECD activity allows the balance output to be redirected
to a 3B21 emulator log file.
1. At the MCC terminal, type and enter: 199 to access the Equipment Configuration
Database (ECD).
Response: 1. database_name:
2. Type and enter: incore
Response: review only:
3. Type and enter: n
Response: journaling:
4. Type and enter: *
Response: Enter Form Name:
5. Type and enter: trbegin
Response: tr_name:
6. Enter CARRIAGE RETURN
Response: Enter Execute, Change. . .
7. Type and enter: e
Response: Enter Form Name:
8. Type and enter: classdef
Response: Enter Database Operation
I=Insert, R=Review, U=Update, D=Delete
9. Type and enter: u
Response: class_name
10. Type and enter:
196
Response: Enter Update, Change...
11. Type and enter: c
Response: Change Field
12. Type and enter: 3
Response: row
13. Type and enter:
1 (if row 1 value is null or value is being replaced)
or
20 (if additional devices are being added to the current list)
Response: 1) or 20)
235-200-150
January 2003
ROUTINE MAINTENANCE
Procedure 5.10.1
Issue 3.00 Page 5.10.1-1