Log out from SCANS and wait for the SCANS system to send the SU(s) over the
SCANS data link (connected to port 0 on the High Speed Bus Interface [HSI]).
This could take up to 24 hours.
Monitor the status of the SCANS download.
Verify download is complete.
Proceed to the “Make Software Update(s) Official,” Procedure 5.4, to apply the
SU. Be sure to review the SU and follow any supplied instructions.
Note: Become completely familiar with the SCANS system prior to running this
procedure.
There is a 24-hour time limit imposed from the time the switch is primed until
SCANS must begin the data session. If SCANS puts the software update load request
in the queue, it may take up to that 24-hour limit to start sending data to the switch.
IN REMOTE STARTED is output to indicate the start of the data session. The IN
REMOTE REPT message may be output periodically during the session to indicate
download progress. Termination of the session is indicated by an IN REMOTE REPT
output message followed immediately by the IN REMOTE STOPPED output message.
PROCEDURE
1. At the MCC, type and enter:
IN:REMOTE:START;
Purpose
Requests that the Administrative Workstation (AW) be put in the
remote-file-receive mode. This message should be entered immediately before
ordering delivery of software update files from the Software Change
Administration and Notification System (SCANS-2), so that the transaction ID
displayed in the IN REMOTE output message can be supplied in the order to
SCANS-2. Software updates must begin to arrive at the Administrative
Workstation within 24 hours. Responsive messages are printed when they are
initially received or when this time limit is reached.
Response: IN REMOTE INITIALIZED
TRANSACTION ID: a TIME: b
Where: a = transaction ID to be supplied to SCANS. This ID value is
required in Step 3.
b = time at which 24-hour timer began in the format hours:minutes.
2. At the SCANS terminal, log in to SCANS per local instructions. Your SCANS
password will be required.
3. Using the SCANS menu-driven system, request a load of the software update(s).
Refer to the SCANS User’s Guide and SCANS Training Manual supplied with
the SCANS login for further detail.
4. SCANS will download the requested SU(s) sometime within the next 24 hours.
Monitor the progress of the download using IN:REMOTE:REPT;.
The possible responses are:
IN REMOTE WAITING
indicates SCANS has yet to download the requested SU(s).
ROUTINE MAINTENANCE
Procedure 5.1
235-200-150
Feburary 2007
Page 5.1-2 Issue 3.00k

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent 5ESS DRM and is the answer not in the manual?

Lucent 5ESS DRM Specifications

General IconGeneral
BrandLucent
Model5ESS DRM
CategoryControl Unit
LanguageEnglish