5. At the MCC Page 1990, type and enter: 2 to start the execution of the PREPARE
section.
Response: The prepare stage box will change from yellow to a flashing blue and
display the word INPROGR. This will continue until the prepare
aborts, stops or completes. If aborted, the indicator box will change
to red and display ABORTED. If the installation is stopped
successfully, the flashing will stop and the indicator box will display
the word STOPPED. If, however, the prepare successfully completes,
the indicator box will change to green and display the word
COMPLTD.
6. To back-out, type and enter: 6, otherwise, proceed to the next step.
Response: The back-out indicator will flash blue. Once completed, the back-out
indicator will appear green and the prepare stage indicator box will
revert back to yellow (not executed or initial state).
7. Type and enter: 3 to install through activate.
Response: The stage indicator will change as in the prepare case. Once activate
completes, proceed to the next step.
8. To back-out or deactivate at this point, type and enter: 6 or 7, otherwise, continue
to the next step.
Response: The back-out or deactivate indicator will flash blue. Once completed,
the corresponding indicator will appear green and the installation
stage indicators will revert back to the point indicated by the
arrows.
9. At the MCC Page 1990, type and enter: 4 to execute SOAK section of message
file.
Response: The stage indicators will change as in the prepare case. Once the
soak section completes, and if there is a default soak time, the soak
timer will start. This will cause the page to repaint with the 1991
page displayed over the lower portion of the 1990 page. The 1991
page will display the SU soaking, the start and end times, and soak
timer options like reset and abort. When the timer completes, the
1991 will disappear and the soak stage indicator will change to
green and read COMPLTD.
10. At the MCC Page 1990, type and enter: 5 to start the execution of the OFFICIAL
section.
Response: The make official stage indicator box will change from yellow to
flashing blue and read INPROGR. Once all the lines in the section
successfully complete, the indicator will change to green and read
COMPLTD.
If during this step the indicator reads: OFFICIAL STOPPED,
perform the following substeps:
(a) At the command line, type and enter: OP:INIT:EMULATOR to perform an
Administrative Workstation (AW) initialization.
Warning: The AW initialization process is NOT service-impacting,
however, video terminal and data link access will be unavailable
and the switching module will be ISOLATED for about 4 to 5
minutes.
ROUTINE MAINTENANCE
Procedure 5.4
235-200-150
January 2003
Page 5.4-2 Issue 3.00