(c) Request 3B21 emulator initialization. Type and enter:UPD:INIT:EMULATOR;
Response: AW completes emulator initialization. MCC displays EAI Page
followed by the 111 Page.
(d) After initialization completes, return to MCC Page 1990.
Did backout complete successfully and “BACK-OUT SECTION
COMPLETED” displayed on the RESPONSE line?
If YES, continue with Step 3e.
If NO, Repeat Step 3 from the beginning. If step 3 is repeated and the
backout does not complete successfully, seek technical support.
(e) If the software update backout included an emulator update (see Step 3a),
then perform the “Backup Administrative Workstation Operating System,”
Procedure 4.4.
4. STOP. YOU HAVE COMPLETED THIS PROCEDURE.