(d) Type and enter: n
Response: 3. journaling
(e) Type and enter: *
Response: UNIX RTR (ODIN) - Data Entry page displayed.
(f) Type and enter: activate
Response: activate form displayed with cursor at 1. copy_inc_to_disk:
(g) Type and enter: yes
Response: ODIN will request the action desired.
(h) Type and enter: e
Response: ODIN returns to the UNIX RTR (ODIN) - Data Entry page.
(i) Type and enter: <
Response: RCV MENU RCV ECD COMPLETED
7. Change Security
(a) At MCC, type and enter message:
SET:RCACCESS,TTY=a,ACCESS=b
Where: a = ttys, ttyt, or ttyv
Where: ttys = TTY18
ttyt = TTY19
ttyv = TTY21
Where b is obtained from INPUT/OUTPUT Manual.
(b) To check on the access code, type and enter message:
OP:RCACCESS,TTY=a
Where: a = ttys, ttyt, or ttyv
Where: ttys = TTY18
ttyt = TTY19
ttyv = TTY21
Response: Access code returned in hexadecimal
8. Backup Office Dependent Data.
Note: Prior to the response there will be completed responses for the switching
module and the AM.
(a) At MCC, type and enter: BKUP:ODD
Response: BKUP ODD COMPLETED
It is recommended that primary disk be backed up and that a shelf copy of
the disks be made.
9. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
235-200-150
October 2005
GROWTH AND DEGROWTH
Procedure 8.4
Issue 3.01 Page 8.4-5