8.9.2 SCC Data Link Growth
1. Type and enter: incore
Response: 2. review only
2. Type and enter: n
Response: 3. journaling
3. Type and enter: *
Response: Enter Form Name:
4. Type and enter: toggle
Response: Enter Form Name:
High-level mode displayed.
5. Type and enter: sdladd
Response: 1. sdl_name
6. Type and enter: SCC or SDL1
Response: 2. port
7. Type and enter: 2
Response: 3. ama_baud_rate
8. Enter CARRIAGE RETURN
Note: This field does not apply for SDL1.
Response: Enter Insert, Change...
9. Type and enter: i
The low-level forms will now be added automatically.
Response: 1. sdl_name
10. Type and enter: <
Response: Enter Form Name:
11. Type and enter: <
Response: Exit this recent change session.
12. To verify SDL1 has been inserted, view the 113 page. SDL1 should appear on this
page.
Note 1: To save the incore ECD changes made in Steps 1 through 11, execute
Steps 16 through 23, otherwise continue with Step 13.
Note 2: SCC must also be grown into the MIN ECD. Execute Steps 13 through
15 to test the MIN ECD growth capability.
13. Type and enter: 199
Response: RCV PARAMETER INFO page displayed with cursor at 1.
database_name
14. Type and enter: rootdmly
Response: 2. review only
GROWTH AND DEGROWTH
Procedure 8.9
235-200-150
April 2004
Page 8.9-2 Issue 3.00G