8.12.3 Configure RMAS RC Access
PROCEDURE
1. At the MCC, type and enter: RST:SDLC=3 to restore SDLC3 to service
Response: RST SDLC 3 COMPLETED
2. At the MCC, type and enter SET:RCACCESS,TTY=”RCOS4”,ACCESS=a;
Where: a = Obtained from the 235–600–700Input Messages Manual(ie
a=1–29,33”)
3. Type and enter: OP:RCACCESS,TTYP=”RCOS4”;
Response: Access code will be returned in hexadecimal.
4. Repeat Steps 2 and 3 for TTYp changles “RCOS5”, “RCOS6”, and “RCOS7”.
5. Type and enter: BKUP:ODD;
6. THIS IS A SAFE STOPPING POINT.