IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
5-103
NOTE: After initial communication, if the inverter is not communicated with for 2 seconds, a
communication fault will occur (CE Memobus ERR).
H05-11 Enter CommandSel 0, 1 1
0 Enter Required Drive requires an Enter command
before accepting any changes to
parameter settings.
1 No EnterRequired Parameter changes are activated
immediately without the Enter
command.
H05-12 Run CommandSel 0, 1 0
0 FWD Run &REV
Run
1 Run & FWD/REV
H05-17 Busy Enter Sel Allows drive to substitute a RAM
enter with a ROM enter when
under heavy CPU load.
0, 1 0
0No ROM Enter
1 RAM Enter
H05-18 MtrSpd Monitor T Motor Speed Monitor Filter Time.
Allows adding a filter to the Motor
Speed monitor (U01-05).
0–100 ms 0
Parameter Display Function Range Default