IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
5-108
L03-21 Acc/Dec P Gain Sets the proportional gain used to
calculate the deceleration rate
during KEB Ride-Thru, OV
suppression function, and Stall
Prevention during deceleration.
0.10–10.00
sec
A01-02 G+/VG+
L03-23 CHP Stall P Sel This function reduces the Stall
Prevention during run level in the
constant power range.
0, 1 0 G+
0 Lvl set in L3-06 Sets the Stall Prevention level that
is used throughout the entire
frequency range.
1 Autom. Reduction Automatic Stall Prevention level
reduction in the constant output
range. The lower limit value is 40%
of L03-06.
L03-24 Mtr Accel Time Sets the time needed to accelerate
the uncoupled motor at rated
torque from stop to the maximum
frequency.
0.001–10.000
sec
O02-04
or E5-
01
G+/VG+
Parameter Display Function Range Default Model
* Default and Range changed by D10-01.