Charge Air Cooler
Maintenance / Disassembly and reassembly
A5.05. 06.04.02.01
M20
en / 25.11.1997 IB002304 2/2
06
Ĺ
ĭ Safety note:
Observe regulations of the manufacturer for cleansing agent to be used, protect skin
against contact with cleansing agent, wear safety glasses. Ensure good ventilation.
2. Reassembly
2.1 Carry out reassembly in reverse order to disassembly.
Note:
Ensure proper fit of the sealing plates in the housing.
2.2 Renew all seals.
2.3 Lubricate hexagon screws (Fig. 1/2) with Molykote paste “G-Rapid Plus” and tighten with a
torque of
M = 60 Nm.