Crankcase Monitoring Device
Inspection / Checking
A5.05. 11.09.01.03
750, 1500, 7500
M20/M25/M32/M43/M453C/M552C/M601C
en / 22.08.2001 IB021758 1/1
11
Ĺ
See also:
Spare parts list: B1.05.11.1.4877
Time requirement: 2 Pers./ 1,00 h
Personnel qualification: skilled engine hand
---------------------------------------------------------------------------------------------------------------------
-
Operating medium: Heavy fuel and distillate fuel
Maintenance:
a) Check the underpressure in the measuring chamber every 750 h
b) Clean the infrared filter and replace the sintered bronze filter
in the measuring attachment every 1.500 h
c) Replace the sintered bronze filter in the pressure control every 7.500 h
Tools:
Test equipment and spare parts.
Service box
Maintenance and trouble shooting: refer to manual C
Attention:
The engine is not monitored in the event of the device malfunctioning.
his can result in engine damage!