Fault tracing
Remedial measures
A3.11.18.02
M20-M601C
en / 08.07.1997 BA000727 4/4
Ĺ
Exhaust gases are blue
Possible cause: Remedy:
Oil in the combustion chamber
Piston rings are sticking For servicing the pistons and rings see,
A5.05.02.07.01.nn
Severe wear and tear of cylinder liner: For checking the cylinder liners see
scoring, ovality A5.05.03.03.01.nn
Valve guide and/or seal are worn For checking the valve guide clearance see
A5.05.01.05.01.nn
______________________________________________________________________________________________
Exhaust gases are white
Possible cause: Remedy:
Exhaust gas condensation due to low
ambient temperatures
Part of the fuel is unburnt because the For engine warm-up see A3.05.18.nn
engine is too cold
Water in the fuel
Water in the charge air manifold see A3.06.06.nn „Charge air cooler“
Leakages in the cylinder head For replacement of cooled valve seat inserts
see A5.05.01.08.03.nn
Cylinder head is cracked
______________________________________________________________________________________________