Operational supervision
Fuel system
A3.06.07.00
M20/M282/M332C/M452/M453C/M551/M552C/M601/M601C
en / 12.02.1996 BA000070 1/1
Ĺ
Fuel system
Drain the water from the day fuel tank and check it at regular intervals.
Inspect the fuel treatment plant.
If the engine is running on heavy fuel, change over to distillate fuel in time. See Changing the
Type of Fuel A3.06.07.nn.
Changing over to distillate fuel may be necessary:
- after lengthy service at partial load operation. (see Partial Load Operation with Heavy Fuel
A3.06.18.nn),
- or before scheduled maintenance work on the fuel system.
"Alarm - leakage fuel injection pipe"
After an alarm and its reset make sure that the fuel leakage pipe is checked with a control
probe, refer to A5.05.01.05.50.nn.