EasyManua.ls Logo

MAK M20 - Emergency Start

MAK M20
456 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning
Putting into operation/starting
A3.05.18.00
M20/M32/M43
en / 30.01.2001 BA000636 3/3
Ĺ
Emergency start
Switch change-over switch S13 to "1 = Engine".
Put emergency-off leaver (10) in operating position at the control station/regulation linkage.
Prelubricate engine.
Switch on lubrication oil - lubrication - or backing pump approximately 5 minutes before starting
the engine. For operating pressure, see A1.05.
Adjust speed slightly higher than n
min
at the speed switch R1.
Start engine manually at the start solenoid or main start-up valve (20).
Keep the starting process as short as possible!
Attention:
The manual start of the engine shall only be performed in the case of a complete standstill
of the engine!
According to its temperature level, run engine slowly up to the operating temperature, see
A3.05.18.nn.
In no case the starting air shut-off valve must be closed during engine operation
(A3.05.11.nn)!