Commissioning
Putting into operation/starting
A3.05.18.00
M20/M32/M43
en / 30.01.2001 BA000636 3/3
Ĺ
Emergency start
• Switch change-over switch S13 to "1 = Engine".
• Put emergency-off leaver (10) in operating position at the control station/regulation linkage.
• Prelubricate engine.
Switch on lubrication oil - lubrication - or backing pump approximately 5 minutes before starting
the engine. For operating pressure, see A1.05.
• Adjust speed slightly higher than n
min
at the speed switch R1.
• Start engine manually at the start solenoid or main start-up valve (20).
Keep the starting process as short as possible!
Attention:
The manual start of the engine shall only be performed in the case of a complete standstill
of the engine!
• According to its temperature level, run engine slowly up to the operating temperature, see
A3.05.18.nn.
• In no case the starting air shut-off valve must be closed during engine operation
(A3.05.11.nn)!