Operational supervision
Partial load operation
A3.06.18.00
M20-M601C
en / 11.12.1997 BA000090 2/2
Ĺ
Note:
If neither a changing-over to destillate fuel nor to high-load operation is possible, an
increased contamination of the lubricating oil is to be expected!
Notes:
The permissible exhaust gas temperature after the turbine (see A3.06.06.nn) must not be
exceeded over the entire operating range, including partial load.
Differing rules may be applicable at partial load, to protect the entire engine, during for
instance, turbocharger failures. See A3.12.00.
If a new engine is first operated only occasionally for several hours in a load range < 50 %, as
is some times the case when a power station is being erected, operation with destilled fuel is
strongly recommended.
If an engine with automatic charge air control is changed over from heavy fuel to distillate fuel
operation, the setting of the charge air temperature control must not be changed.