Decommissioning
Decommissioning/Stopping
A3.07.18.02
M20/M25/M32/M43
en / 11.05.2000 BA000630 4/4
Ĺ
Keep lubrication oil system warm by means of permanent separation to prevent an
accumulation of condensation products and sludge.
Switch off ventilation for engine room only if required to make cooling-off of the engine more
difficult.
Before a long term operation stop (e.g. down time up to 4 weeks), heavy oil engines must be
changed over to distillate fuel several hours beforehand (see A3.06.07.nn).
In the case of down times of more than 4 weeks, the engine must be conserved. Climatic conditions
and storage time determine the scope of the measures (see A3.09.01.nn or A3.09.02.nn).