Preservation
Short term preservation
A3.09.01.00
M20-M601C
en / 24.06.1996 BA000118 2/3
Ĺ
2.2 Lubricating oil system
Cleaning the lubricating oil duplex filters, see A5.05.08.04.01.nn.
Note:
The lubricating oil remains in the circuit if the values required for engine operation
are in order (see A4.05.08.nn).
Recommendation: Pump fresh lubricating oil through the engine circuit, until clean
oil drips out of the last small end bearing.
If the engine is separated from the plant, remove lubricating oil. Then firmly seal each
connection with blind flange or stop plug.
2.3 Cooling water system
Cool the engine down to 30 °C and drain the cooling water.
Note:
The cooling water tracts are protected by the corrosion inhibiter in the cooling water,
see A4.05.09.02.
Engines with caged exhaust valves: fill the water spaces of the cages with glycol if there is
a danger of frost, see 1.5.
2.4 Crancase, running gear, cam shaft, roller tappets for valves, injection pumps, charge air
manifold
Spray the parts with preserving oil (see 1.2) and make sure that all areas of the crankshaft,
cam shaft, connecting rods and gears are coated.
Open the charge air manifold and spray the interior with preservation oil (see 1.2) and
reclose.
2.5 Upper valve rockers
Slacken and remove rocker gear cover.
Spray the parts fitted in the cylinder heads with preservation oil (see 1.2).
Clean the seating of the rocker gear cover.
Fit and tighten the rocker gear cover.