18.2.6 Fluid Level Pressure
Transmission repetition rate: 50 ms
Data length: 8 bytes
Identifier: 0x18 FE EF 27
Byte 1: Engine fuel delivery pressure
40 mbar per bit
0 mbar offset
Range: 0 bar ... 10 bar
SAEJ1939-71: SPN 94
Byte 2: Extended Crankcase Blow-by Pressure
0x FF
Not supported
Byte 3: Engine oil level
0.4 % per bit
0 % offset
Range: 0 % ... 100 %
SAEJ1939-71: SPN 94
Byte 4: Engine oil pressure
40 mbar per bit
0 mbar offset
Range: 0 bar ... 10 bar
SAEJ1939-71: SPN 100
Byte 5, 6: Engine crankcase pressure
0x FF FF
Not supported
Byte 7: Engine coolant pressure
10 mbar per bit
0 mbar offset
Range: 0 bar ... 5 bar
SAEJ1939-71: SPN 109
Byte 8: Engine Coolant Level
0.4 % per bit
0 % offset
Range: 0 % ... 100 %
SAEJ1939-71: SPN 111
only two states supported:
0 % Low level detected