Parametrization start/stop
125
Read this manual carefully before starting any work!
This is particularly applicable to the chapter “General Safety Instructions”
and the respective safety instructions in the chapters.
14.2 Possible error messages
Error message: “Missing Start/Stop stands”
The start/stop stand with the ID 2 is not found in
the system configuration shown on the right.
Possible causes/procedure:
S The display with the parametrized start/stop
stand ID 1 is switched off Switch on the
display/check CAN connection
Error message: “Unconfigured Start/Stop stands”
A start/stop stand with the ID 1 is found in the
system configuration shown on the right, although
this was not parametrized.
Possible causes/procedure:
S Add start/stop stand Re-parametrize the
system.
S Search for the display with the parametrized
start/stop stand ID 1 Remove the start/stop
stand there.
See “Display configuration” - set the start/stop
stand in the display, page 124
Error message: “Defective Start/Stop stands”
The start/stop stand with the ID 1 is detected as
defective in the system configuration shown on the
right.
Possible causes/procedure:
S Display off / on.
S Re-parametrize the start/stop stand with the
ID 1 “Unregister stand”, then configure again.