Control and operation
70
Read this manual carefully before starting any work!
This is particularly applicable to the chapter “General Safety Instructions”
and the respective safety instructions in the chapters.
Local control
With local control, the engine and the gearbox can be controlled via 8 buttons on the alarm display.
The following control commands can be executed via the buttons:
S Gearbox switch to forwards ▲
S Switch the gearbox to neutral “N”
S Gearbox switch to reverse ▼
S Engine speed increase (RPM+)
S Engine speed reduction (RPM-)
S Engine start
S Engine stop
Local control - non-classified version
Activation of local control is effected via pressing
the “Local ON/OFF” button on the alarm display
twice.
Request - on first activation:
flashing LED behind the 8 buttons
flashing green bar on the screen
acoustic message active
Confirmation - by repeated activation:
static LED behind the 8 buttons
static green bar on the screen
→ Local control is now active!
Deactivation via the “Local ON/OFF” button →
green bar disappears.
Local control - classified version
Activation:
Request by pressing the “Local” button (1) on the
E-box:
flashing „Local“ button
flashing „Local“ icon in the display at the top
right
acoustic message active
Confirmation is via activation of the “Local ON”
button on the alarm display:
„Local“ button lights up
„Local“ icon lights up in the display at the top
right
→ Local control is now active!
Deactivation via the „Remote“ button on the E-box

Table of Contents