Control and operation
75
Read this manual carefully before starting any work!
This is particularly applicable to the chapter “General Safety Instructions”
and the respective safety instructions in the chapters.
Engine settings
The following settings can be made on this page
(password are required):
Prerequisites for adjusting the values:
1 Idle speed
Idle speed is set to 600 rpm ex works.
S Engine at idle
S Driving lever must stand at 0 %
2 Intermediate speed control - The PI behavior (control mode) of the EDC controller is set here
Parameter setting 0 1 2 3
Description
Control mode standard fast slow very slow
Load response fast standard standard standard
3 Smoke quantity characteristic map
0 = Standard
1 = slow acceleration
2 = fast acceleration