Maintenance overview
5.4 Measures required for winch monitoring
5 - 26 3 302 744 en Maintenance manual
GMK5250L
09.03.2018
5.4.3 Example
A GMK5250L is equipped with a separate operating hours counter for the
hoist and is classified by Manitowoc Crane Group Germany GmbH as fol-
lows:
The used proportion S of theoretical service life is calculated based on the
individual inspection intervals as follows:
1
st
inspection (1
st
year)
The truck crane was used for assembly work during the previous year:
Load spectrum L 1, i.e. Km
1
= 0.125.
The operating hours counter for the main hoist reads 160 h, i.e. T1 = 160 h.
The used proportion S
1
of theoretical service life after the first inspection
therefore is:
Remaining theoretical service life:
D1 = 3,200 h -160 h = 3,040 h.
The above values are entered in the table (see table example p. 5 - 28).
2
nd
inspection (2
nd
year)
The truck crane was used for unloading work on docks: Load spectrum:
L 3, i.e. Km
2
= 0.5.
The operating hours counter for the main hoist reads 640 h, i.e. during this
period: 640 hrs. – 160 h = 480 h (160 h were used during the first year)
T2 = 480 h
Power unit group: M3
Load spectrum: Light L 1, Km = 0.125
Theoretical service life: D = 3,200 h
S
i
0.125
0.125
---------------
160 h× 160 h==