Grove Published 01-29-2015, Control # 512-01 9-11
TMS700E SERVICE MANUAL LUBRICATION
9
33. Upper Lift Cylinder Pivot Pin
Lube Type - EP-MPG
Lube Interval - 500 hours or every 3 months, whichever
interval occurs first
Lube Amount - Until grease extrudes
Application - 1 grease fitting
34. Lower Lift Cylinder Pivot Pin
Lube Type - EP-MPG
Lube Interval - 500 hours or 3 months, whichever
interval occurs first
Lube Amount - Until grease extrudes
Application - 2 grease fittings
35. Main Hoist
Lube Type - EPGL-5H
Lube Interval - Check and fill every 50 hours or weekly,
whichever interval occurs first. Verify drain plug is visible
in upper cutout, the machine is level from side to side,
the hoist has not been operated for at least 20 minutes
and the temperature is 21°C ± 6.7°C (70°F ± 20°F).
Drain and fill every 1000 hours or 12 months.
Lube Amount - Capacity - 14.7 l (15.5 qt)
Application - Fill until level is visible in sight gauge.
36. Auxiliary Hoist (Optional)
Lube Type - EPGL-5H
Lube Interval - Check and fill every 50 hours or weekly,
whichever interval occurs first. Verify drain plug is visible
in upper cutout, the machine is level from side to side,
the hoist has not been operated for at least 20 minutes
and the temperature is 21°C ± 6.7°C (70°F ± 20°F).
Drain and fill every 1000 hours or 12 months.
Lube Amount - Capacity - 14.7 l (15.5 qt)
Application - Fill until level is visible in sight gauge.
37. Cable Guard Roller and Guide Roller
Lube Type - EP-MPG
NOTE: Rollers may or may not have bearings that need
lubrication. Those that do will have grease fittings.
Lubricate more frequently than interval indicated, if
environmental conditions and/or operating
conditions necessitate.
Lube Interval - 250 hours or 3 months, whichever
interval occurs first.
Lube Amount - Until grease extrudes
Application - To each grease fitting.
BOOM, BOOM EXTENSION, AND BOOM
ACCESSORIES LUBRICATION
38. Boom Pivot Shaft
Lube Type - EP-MPG
Lube Interval - 250 hours or 3 months, whichever
interval occurs first
Lube Amount - Until grease extrudes
Application - 2 grease fittings, one on each side
39. Extend Cable Sheaves
Lube Type - EP-MPG
Lube Interval - 250 hours or 3 months, whichever
interval occurs first
Lube Amount - Until grease extrudes
Application - 1 grease fitting; extend boom for entry
through access holes in Section 4 and Section 3s.
Reference Only

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove TMS700E and is the answer not in the manual?

Manitowoc Grove TMS700E Specifications

General IconGeneral
BrandManitowoc
ModelGrove TMS700E
CategoryConstruction Equipment
LanguageEnglish

Related product manuals