44. Boom Section Upper and Lower Wear Pads
Lube Type - EP-MPG
Lube Interval - 50 hours or 1 week, whichever occurs
first
Lube Amount - Thoroughly coat all areas the wear pad
moves on.
Application - By brush; 6 places; with boom in extended
position.
45. Upper Boom Nose Sheave
Lube Type - EP-MPG
Lube Interval - 250 hours or 3 months, whichever occurs
first
Lube Amount - Until grease extrudes
Application - 1 grease fitting per sheave (2 total)
46. Lower Boom Nose Sheave
Lube Type - EP-MPG
Lube Interval - 250 hours or 3 months, whichever occurs
first
Lube Amount - Until grease extrudes
Application - 1 grease fitting per sheave (5 total)
47. Boom Extension Sheaves
Lube Type - EP-MPG
Lube Interval - 250 hours or 3 months, whichever occurs
first
Lube Amount - Until grease extrudes
Application - 1 grease fitting
48. Boom Extension Mast Sheave
Lube Type - EP-MPG
Lube Interval - 500 hours or 6 months, whichever occurs
first
Lube Amount - Until grease extrudes
Application - 1 grease fitting
49. Auxiliary Boom Nose Sheave
Lube Type - EP-MPG
Lube Interval - 250 hours or 3 months, whichever
interval occurs first
Lube Amount - Until grease extrudes
Application - 1 grease fitting
50. Hook Block Swivel Bearing
Lube Type - EP-MPG
Lube Interval - 250 hours or 3 months, whichever
interval occurs first
Lube Amount - Until grease extrudes
Application - 1 grease fitting
51. Hook Block Sheaves
Lube Type - EP-MPG
Lube Interval - 250 hours or 3 months, whichever
interval occurs first
Lube Amount - Until grease extrudes
Application - 1 grease fitting per sheave
(5 fittings total - 60 ton)
(4 fittings total - 50 ton)
(3 fittings total - 40 ton)
52. Headache Ball Swivel Top
Lube Type - EP-MPG
Lube Interval - 250 hours or 3 months, whichever
interval occurs first
Lube Amount - Until grease extrudes
Application - 1 grease fitting
WIRE ROPE LUBRICATION
Wire rope is lubricated during manufacturing so that the
strands, and individual wires in strands, may move as the
rope moves and bends. A wire rope cannot be lubricated
sufficiently during manufacture to last its entire life.
Therefore, new lubricant must be added periodically
throughout the life of a rope to replace factory lubricant which
is used or lost. For more detailed information concerning the
lubrication and inspection of wire rope, refer to Wire Rope,
page 1-16.
Reference Only

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove TMS700E and is the answer not in the manual?

Manitowoc Grove TMS700E Specifications

General IconGeneral
BrandManitowoc
ModelGrove TMS700E
CategoryConstruction Equipment
LanguageEnglish

Related product manuals