76
© 2013 McNeilus Truck and Manufacturing, Inc.
Contender Front Loader
Operation
4.4.7.1 Filling the Tank
The tank can be lled through the opper valve (Figure 36,
Item 1) or through the optional gate valve (Figure 36, Item 2).
1
2
OR
Figure 36
4.4.7.2 Pressurizing the Water Tank
WARNING
Never drive the truck with the water tank
pressurized.
Serious personal injury or death may occur.
WARNING
Never pressurize an empty water tank.
Serious personal injury or death may occur.
1. Fill the tank to the desired level.
WARNING
Pressure in the water tank should never
exceed 55 psi. If pressure exceeds 55 psi,
depressurize tank immediately and replace
with new McNeilus air regulator valve.
NEVER pressurize an empty tank.
NEVER modify tank in any way.
Operating in excess of 55 psi, pressurizing
an empty tank, or modifying the tank may
cause serious personal injury or death.