72 MDS iNET 900 Users Guide MDS 05-2806A01, Rev. A
2.12 LOGGED OPERATIONAL EVENTS
The iNET’s microprocessor monitors many operational parameters and
logs them as various classes of “events”. If the event is one that affects
performance, it is an “alarm” of which there are three levels. There are
also normal or routine events such as those marking the rebooting of the
system, implementation of parameter changes and external access to the
iNET Management System. Table 2-5 summarizes these classifications.
The log is divided into two partitions: 1. Error and 2. Operation. All
alarms are stored in the Error Log and routine events are stored in the
Operations Log.
Active Image Number of currently active
firmware image
1 1, 2
Reboot Device Reboots the iNET unit. This
action will remove the unit
from providing any network
services until is
re-associated or on-line.
Configuration Scripts
TFTP Host Address IP address of the host that
the file will be sent via TFTP
192.168.1.1 Any standard IP
address
Filename Name of the firmware file to
TFTP to/from the iNET
null string Any 40-character
alphanumeric string
TFTP Timeout Time in seconds the TFTP
server will wait for a packet
ACK (acknowledgment)
from the iNET before
suspending the file transfer
10 seconds 10 to 120 seconds
Retrieve File Name of the firmware file to
be transferred via TFTP into
the radio
n/a n/a
Send File Service to send the
configuration script file via
TFTP
n/a n/a
Authorization Key Enter Authorization Key
string to enable additional
services
––
Table 2-12. Maintenance Menu Structure and Functions (Continued)
Submenu Description Default Acceptable Range
Table 2-13. Diagnostic Tools
Submenu Description Default
Loopback Test Local data loopback within iNET unit. OFF
Radio Test User-selected tools for radio testing
Test Mode ON/OFF OFF
Frequency Carrier frequency of test signal (TX & RX) 915.0000 MHz
TX Output Power Power output under test 30 dBm
TxKey Enabled/Disabled Unkeyed
RSSI Received signal strength in dBm
Ping Utility Submenu to send PING to IP address

Table of Contents