Document reference MAMPS-HW/E HARDWARE MANUAL
Edition 18 - March 2022 VM600 machinery protection system (MPS)
xvii
Hazardous voltages and the risk of electric shock
Hot surfaces and the risk of burning
Heavy objects and the risk of injury
HAZARDOUS VOLTAGES EXIST WITHIN A VM600 RACK.
W
HEN A CARD, PANEL OR POWER SUPPLY IS REMOVED FROM A VM600 RACK, THE
RACK
BACKPLANE – CONTAINING HAZARDOUS VOLTAGES – IS EXPOSED AND THERE
IS
THE RISK OF ELECTRIC SHOCK, AS INDICATED BY THE USE OF THE FOLLOWING
WARNING
LABEL ON THE EQUIPMENT:
R
EGARD ANY EXPOSED COMPONENT, CONNECTOR OR PRINTED CIRCUIT BOARD (PCB)
AS A POSSIBLE SHOCK HAZARD AND DO NOT TOUCH WHEN ENERGISED.
F
OR SAFETY REASONS, ANY VM600 RACK SLOT (CARD POSITION) NOT POPULATED
BY
A VM600 CARD MUST BE COVERED BY A BLANK PANEL.
F
AILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN DEATH, SERIOUS INJURY,
AND/OR EQUIPMENT DAMAGE.
S
EE 8INSTALLATION FOR FURTHER INFORMATION.
HOT SURFACES CAN EXIST WITHIN AND ON A VM600 RACK.
D
EPENDING ON THE AMBIENT OPERATING TEMPERATURE AND POWER CONSUMPTION,
AND THE INSTALLATION AND COOLING OF A VM600 RACK, THE TOP OF THE RACK CAN
BECOME
HOT TO TOUCH AND THERE IS THE RISK OF BURNING WHEN HANDLING THE
RACK
, AS INDICATED BY THE USE OF THE FOLLOWING WARNING LABEL ON THE
EQUIPMENT
:
R
EGARD THE TOP OF A VM600 RACK AS A HOT SURFACE AND DO NOT TOUCH
UNLESS
COOL.
F
AILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN INJURY.
A FULLY POPULATED VM600 SYSTEM RACK (ABE04X) WITH VM600 CARDS AND
RPS6U RACK POWER SUPPLIES INSTALLED IS A HEAVY OBJECT.
D
EPENDING ON THE NUMBER OF CARDS AND RACK POWER SUPPLIES INSTALLED, A
VM600 SYSTEM RACK CAN BE TOO HEAVY TO HANDLE MANUALLY BY ONE PERSON
AND
THERE IS THE RISK OF INJURY DURING INSTALLATION OR REMOVAL.
A
CCORDINGLY, A FULLY POPULATED VM600 SYSTEM RACK SHOULD BE CONSIDERED
AS
A HEAVY OBJECT THAT REQUIRES TWO PEOPLE TO LIFT, LOWER OR OTHERWISE
HANDLE
MANUALLY.
A
LTERNATIVELY, THE RPS6U RACK POWER SUPPLIES (THE HEAVIEST SYSTEM
COMPONENTS
AND EASILY REMOVABLE), AND THEN VM600 CARDS AS NECESSARY,
CAN BE REMOVED FROM A VM600 SYSTEM RACK IN ORDER TO REDUCE THE WEIGHT
AND
ALLOW ONE PERSON TO SAFELY HANDLE MANUALLY.
F
AILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN INJURY.

Table of Contents

Other manuals for Meggitt vibro-meter VM600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Meggitt vibro-meter VM600 and is the answer not in the manual?

Meggitt vibro-meter VM600 Specifications

General IconGeneral
BrandMeggitt
Modelvibro-meter VM600
CategoryProtection Device
LanguageEnglish