5B-32 - MID-SECTION 90-830234R3 DECEMBER 1997
BRUSH REPLACEMENT
1. Brush replacement is required if brushes are
pitted, chipped or if distance between the brush
pigtail and end of brush holder slot is 1/16 in.
(1.6mm) or less. Check distance with armature.
a
51350
a - 1/16 in. (1.6mm)
2. To replace brush card, remove metal connectors.
a
a
51351
a - Metal Connectors
3. Install new brush card.
4. Crimp new metal connectors onto wires.
IMPORTANT: If metal connectors are not insu-
lated with shrink tube, bend metal connectors
away from motor housing to prevent shorts.