5E-12 - MID-SECTION 90-830234R3 DECEMBER 1997
Shock Function (Valve Closed)
Accumulator
Gas Pressure
400 PSI
a
b
p
o
n
m
l
j
k
i
h
g
f
e
d
c
a - Shock Rod
b - End Cap
c - Accumulator
d - Accumulator Piston
e - Accumulator Check Valve
f - Camshaft Lever
g - Manifold
h - Down Fast Transfer Valve
i - Down Slow Transfer Valve
j - Up Fast Transfer Valve
k - Surge Valve
l - Cylinder
m- Memory Piston
n - Shock Piston
o - Shock Return Valve
p - Impact Relief Valve

Table of Contents