2A-28 - ELECTRICAL 90-830234R3 DECEMBER 1997
CDM Stop Diode Trouble Shooting
2 Cyl.:
CDM #1 gets its charging ground path through CDM #2
CDM #2 gets its charging ground path through CDM #1
A shorted Stop Diode in either CDM would prevent the opposite one from sparking.
12
3 Cyl.:
CDM #1 gets its charging ground path through CDM #2 or #3
CDM #2 and #3 get their charging ground path through CDM #1
A shorted Stop Diode in CDM #1 would prevent CDMs #2 and #3 from sparking.
A shorted Stop Diode in CDM #2 or #3 would prevent CDM #1 from sparking.
123
4 Cyl.:
CDM #1 and #2 get their charging ground path through CDM #3 or #4
CDM #3 and #4 get their charging ground path through CDM #1 or #2
A shorted Stop Diode in CDM #1 or #2 would prevent CDMs #3 and #4 from sparking.
A shorted Stop Diode in CDM #3 or #4 would prevent CDM #1 and #2 from sparking.
12 34
6 Cyl.:
All CDMs get their charging ground path independently through the stator’s white leads.
A shorted Stop Diode in any one CDM will prevent at least 2 other CDMs from sparking
135 246