Chapter 5 Trigger System
57
Set CH2 as trigger signal source
Set CH3 as trigger signal source
Set CH4 as trigger signal source
Set trigger on positive signal slope
Set trigger on negative signal slope
Set trigger on detecting a signal slope change
Trigger when the signal slope hold time is smaller than T
Trigger when the signal slope hold time is greater than T
Trigger when the signal slope hold time is smaller than upper
limit T1 and greater than lower limit T2
Set the trigger signal slope hold time
Set CH1 slope status as rise and hold time less than 1ms. The steps are as follows:
1) Tap “Trigger” on the main menu to open the trigger menu, select the slope trigger in the trigger type, and
set the slope trigger as follows, as shown in Figure 5-26:
⚫ Trigger source: CH1;
⚫ Edge: Rise;
⚫ Slope hold time: 1us;
2) Adjust trigger level, adjust High or Low trigger level, click arrow at both ends of the chute Switch the
trigger level between High and Low.