Technical Information
47
CVA 265x & CVA 266x
Remedy:
Note:
The cappuccinatore components are easier to assemble when they are
slightly damp.
1. Rinse all cappuccinatore components under cold water.
2. Reassemble the cappuccinatore; see Section 040-4.1.
3.2 Water Tank Drains Empty
Symptom:
The water tank drains empty and the drip tray is full to the brim even though
the water tank has been firmly pushed in as far as possible and has clipped
properly into place at the bottom.
Cause:
Too little tolerance and too little overlap of the seal in the water connection
point.
Remedy:
A tighter seal has been installed as a series modification.
Note:
As the cap will usually be damaged when removing the seal, this should also
be ordered and replaced at the same time.
1. Remove the valve housing seal; see Section 010-4.7.
2. Install a new seal.
3. Install a new cap.
4. Explain to the customer that the water tank is now more difficult to insert
and that it must be pushed in fully, and it must be ensured that the bottom
retainers have engaged.