Technical Information
63
CVA 265x & CVA 266x
3 Fault Repair
3.1 Display Message Summary
Display Message Cause Remedy
Chamber empty - Please
refill
Selected chamber is empty Refill with coffee capsules
Please fill with fresh water
Reminder to fill water tank with
fresh water
Fill water tank with fresh
water
Please fill and replace the
water container
Water tank empty or not
installed
Fill and install water tank
Please empty waste
container and then replace it
Waste container full or not
installed
Empty waste container and
reinstall it
Please set the time of day
Appliance was disconnected
from main power
Set the time of day
Please empty drip tray
Drip tray full Empty and clean drip tray
Please use descaling funnel
and close the door
Descaling funnel not installed
Remove capsule plate and
install descaling funnel in its
place
Please insert capsule plate
Capsule plate or capsule cage
not installed, or descaling
funnel still installed
Remove descaling funnel, if
necessary, and install
capsule plate or capsule
cage
Please insert capsule
magazine
Capsule magazine not
installed or sensor under the
drawer is dirty
Install capsule magazine and
clean sensor with a cloth
Please open the valve
Steam valve closed
Press steam lever down to
open
Please close the valve
Steam valve open
Slide steam lever upward to
close
Confirm to start
Descaling process or other
procedure needs to be
continued
Press right switch knob
Confirm to start
Descaling process needs to be
continued
Press right switch knob
Empty
Selected chamber has not
been allocated a coffee type
Allocate a coffee to type to
the chamber
No. of uses until descaling
has to be done
The appliance counts the
number of servings (coffee, hot
water, steam) until it must be
descaled. Once this number
has been reached the
appliance is blocked and
cannot be used until descaling
is performed.
Perform the descale
procedure
Table 060-2: Display Message Summary